{"id":823,"date":"2026-08-24T22:22:18","date_gmt":"2026-08-24T22:22:18","guid":{"rendered":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823"},"modified":"2026-08-24T22:27:23","modified_gmt":"2026-08-24T22:27:23","slug":"substrate-moisture-tile-failure-evaluating-conditions-beneath-the-assembly","status":"publish","type":"post","link":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823","title":{"rendered":"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"823\" class=\"elementor elementor-823\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e009bc4 e-flex e-con-boxed e-con e-parent\" data-id=\"e009bc4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<h3 data-interaction-id=\"bf22565\" class=\"e-bf22565-06e0cc1 e-heading-base\">An analysis of vapor emission, material interaction, and evidentiary requirements in moisture-related claims<\/h3>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e54fe3 elementor-widget elementor-widget-text-editor\" data-id=\"5e54fe3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><em>By Gil Chotam &amp; Greg Andrews | National Tile and Stone Authority (NTSA)<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e53b8c9 e-flex e-con-boxed e-con e-parent\" data-id=\"e53b8c9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-574f639 elementor-widget elementor-widget-text-editor\" data-id=\"574f639\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-size: 21px;\">Moisture-related conditions are commonly attributed to installation error based on visible symptoms, despite the fact that substrate moisture levels are typically established prior to installation.<\/span><\/p><p>Where elevated moisture or active vapor transmission is present, the long-term performance of the tile assembly may be affected regardless of installation technique.<\/p><h3>Moisture Behavior, Failure Patterns, and Evidentiary Considerations<\/h3><p>Moisture-related failures typically develop over time rather than presenting as immediate or catastrophic events. Common indicators include hollow-sounding tile, darkening of stone, debonding, efflorescence, curling, and surface staining. These symptoms may resemble installation deficiencies, particularly in the absence of pre-installation moisture data.<\/p><p>Substrate moisture (moisture within the substrate) can interfere with bond development. In cementitious systems, excess moisture may alter curing conditions, affect polymer dispersion in thin-set mortars, and reduce bond strength. These effects may not be immediately visible but can result in progressive deterioration under normal service conditions.<\/p><p>Concrete slabs present a particular challenge. Moisture within concrete often exists as vapor rather than free water. Where vapor pressure below the slab exceeds conditions above, moisture migrates upward through the assembly. This vapor movement can transport soluble salts and alkalinity, affecting both setting materials and stone.<\/p><p>Mortar beds behave differently due to their permeability. Substrate moisture may remain within the matrix for extended periods, particularly where installation occurs under cold or humid conditions. Surface dryness does not necessarily reflect internal moisture content. Tile bonded to a damp mortar bed may exhibit delayed bond failure consistent with moisture interference during curing.<\/p><p>Backer boards introduce additional variables. Cementitious boards may absorb moisture during storage or prior to installation, while foam-based systems may restrict moisture movement at the interface. In each case, the substrate moisture condition may influence performance independent of installation technique.<\/p><h3>Substrate Moisture Testing<\/h3><p>In forensic evaluation, the absence of pre-installation moisture data significantly limits the ability to establish causation. Without testing, it may be difficult to distinguish between failure related to substrate conditions and failure related to installation practices.<\/p><p>Moisture testing methods, including calcium chloride testing, in situ probes, and surface moisture mapping, provide objective data regarding substrate condition. Documentation of environmental conditions, curing periods, and site protection further supports interpretation of observed failures.<\/p><p>Where such data is not available, analysis may rely on indirect indicators and pattern recognition, which may introduce uncertainty.<\/p><h3>Responsibility and Documentation<\/h3><p>In construction defect cases, the presence or absence of moisture documentation often influences the allocation of responsibility.<\/p><p>Where testing was requested and not performed, or where installation proceeded over substrates that did not meet moisture criteria, the relationship between decision-making and outcome becomes a central factor in the analysis.<\/p><p>Conversely, where moisture conditions were not evaluated or documented, distinguishing between environmental causes and installation-related issues becomes more complex.<\/p><h3>Conclusion<\/h3><p>Substrate moisture plays a critical role in the performance of tile and stone assemblies. Moisture-related failures often reflect conditions present prior to installation rather than deficiencies in workmanship alone.<\/p><p>Accurate evaluation requires consideration of vapor movement, material interaction, and available documentation.<\/p><p>In construction defect analysis, moisture testing is essential to establishing whether an assembly was installed under conditions suitable for long-term performance.<\/p><h3>NTSA Caveat<\/h3><p>This article is based on field observations, case reviews, and professional experience. It is intended to highlight patterns relevant to construction defect evaluation. Final determinations should be made based on project-specific documentation, testing, and coordination with all relevant parties.<\/p><p><a href=\"https:\/\/www.ntsaexperts.com\">National Tile and Stone Authority<\/a> (NTSA) provides forensic consulting and expert witness services in tile and stone-related matters.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>An analysis of vapor emission, material interaction, and evidentiary requirements in moisture-related claims By Gil Chotam &amp; Greg Andrews | National Tile and Stone Authority (NTSA) Moisture-related conditions are commonly attributed to installation error based on visible symptoms, despite the fact that substrate moisture levels are typically established prior to installation. Where elevated moisture or&#8230;<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[60],"tags":[68,70],"class_list":["post-823","post","type-post","status-publish","format-standard","hentry","category-forensics-failures","tag-installation-failure","tag-substrate-moisture"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.0.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Gil Chotam &amp; Greg Andrews\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.0.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"NTSA Articles - Learn about tile &amp; stone products.\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Substrate Moisture &amp; Conditions Beneath the Assembly\" \/>\n\t\t<meta property=\"og:description\" content=\"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-08-24T22:22:18+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-08-24T22:27:23+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Substrate Moisture &amp; Conditions Beneath the Assembly\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#blogposting\",\"name\":\"Substrate Moisture & Conditions Beneath the Assembly\",\"headline\":\"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly\",\"author\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?author=4#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/#organization\"},\"datePublished\":\"2026-08-24T22:22:18+00:00\",\"dateModified\":\"2026-08-24T22:27:23+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#webpage\"},\"articleSection\":\"Forensics &amp; Failures, Installation Failure, Substrate Moisture\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?cat=60#listItem\",\"name\":\"Forensics &amp; Failures\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?cat=60#listItem\",\"position\":2,\"name\":\"Forensics &amp; Failures\",\"item\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?cat=60\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#listItem\",\"name\":\"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#listItem\",\"position\":3,\"name\":\"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?cat=60#listItem\",\"name\":\"Forensics &amp; Failures\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/#organization\",\"name\":\"NTSA Articles\",\"description\":\"Learn about tile & stone products.\",\"url\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?author=4#author\",\"url\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?author=4\",\"name\":\"Gil Chotam &amp; Greg Andrews\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7a3440ede9e27cec8a1a92e0a69e66eb6aa780d208caf5a7118c61ad6d6f12c1?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Gil Chotam &amp; Greg Andrews\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#webpage\",\"url\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823\",\"name\":\"Substrate Moisture & Conditions Beneath the Assembly\",\"description\":\"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?p=823#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?author=4#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/?author=4#author\"},\"datePublished\":\"2026-08-24T22:22:18+00:00\",\"dateModified\":\"2026-08-24T22:27:23+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/#website\",\"url\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/\",\"name\":\"NTSA Articles\",\"description\":\"Learn about tile & stone products.\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ntsaexperts.com\\\/NTSA-articles\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Substrate Moisture & Conditions Beneath the Assembly","description":"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.","canonical_url":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#blogposting","name":"Substrate Moisture & Conditions Beneath the Assembly","headline":"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly","author":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?author=4#author"},"publisher":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/#organization"},"datePublished":"2026-08-24T22:22:18+00:00","dateModified":"2026-08-24T22:27:23+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#webpage"},"isPartOf":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#webpage"},"articleSection":"Forensics &amp; Failures, Installation Failure, Substrate Moisture"},{"@type":"BreadcrumbList","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles#listItem","position":1,"name":"Home","item":"https:\/\/www.ntsaexperts.com\/NTSA-articles","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?cat=60#listItem","name":"Forensics &amp; Failures"}},{"@type":"ListItem","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?cat=60#listItem","position":2,"name":"Forensics &amp; Failures","item":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?cat=60","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#listItem","name":"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#listItem","position":3,"name":"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly","previousItem":{"@type":"ListItem","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?cat=60#listItem","name":"Forensics &amp; Failures"}}]},{"@type":"Organization","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/#organization","name":"NTSA Articles","description":"Learn about tile & stone products.","url":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/"},{"@type":"Person","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?author=4#author","url":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?author=4","name":"Gil Chotam &amp; Greg Andrews","image":{"@type":"ImageObject","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/7a3440ede9e27cec8a1a92e0a69e66eb6aa780d208caf5a7118c61ad6d6f12c1?s=96&d=mm&r=g","width":96,"height":96,"caption":"Gil Chotam &amp; Greg Andrews"}},{"@type":"WebPage","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#webpage","url":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823","name":"Substrate Moisture & Conditions Beneath the Assembly","description":"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/#website"},"breadcrumb":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823#breadcrumblist"},"author":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?author=4#author"},"creator":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?author=4#author"},"datePublished":"2026-08-24T22:22:18+00:00","dateModified":"2026-08-24T22:27:23+00:00"},{"@type":"WebSite","@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/#website","url":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/","name":"NTSA Articles","description":"Learn about tile & stone products.","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/#organization"}}]},"og:locale":"en_US","og:site_name":"NTSA Articles - Learn about tile &amp; stone products.","og:type":"article","og:title":"Substrate Moisture &amp; Conditions Beneath the Assembly","og:description":"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.","og:url":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823","article:published_time":"2026-08-24T22:22:18+00:00","article:modified_time":"2026-08-24T22:27:23+00:00","twitter:card":"summary_large_image","twitter:title":"Substrate Moisture &amp; Conditions Beneath the Assembly","twitter:description":"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims."},"aioseo_meta_data":{"post_id":"823","title":"Substrate Moisture &amp; Conditions Beneath the Assembly","description":"Vapor emission, material interaction, evidentiary requirements in moisture-related claims. Substrate moisture a factor in failure, construction defect claims.","keywords":null,"keyphrases":{"focus":{"keyphrase":"substrate moisture","score":0,"analysis":[]},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-08-24 21:47:22","updated":"2026-08-24 22:27:23","focus_keyword":"substrate moisture","additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ntsaexperts.com\/NTSA-articles\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?cat=60\" title=\"Forensics &amp; Failures\">Forensics &amp; Failures<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tSubstrate Moisture &amp; Tile Failure: Evaluating Conditions Beneath the Assembly\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.ntsaexperts.com\/NTSA-articles"},{"label":"Forensics &amp; Failures","link":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?cat=60"},{"label":"Substrate Moisture &#038; Tile Failure: Evaluating Conditions Beneath the Assembly","link":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/?p=823"}],"_links":{"self":[{"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=\/wp\/v2\/posts\/823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=823"}],"version-history":[{"count":4,"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=\/wp\/v2\/posts\/823\/revisions"}],"predecessor-version":[{"id":827,"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=\/wp\/v2\/posts\/823\/revisions\/827"}],"wp:attachment":[{"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ntsaexperts.com\/NTSA-articles\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}